|
-
Parts And PC : $10.20
-
PC board (only): $3.85
|
Switch your points with this...
|
CAPACITOR
DISCHARGE UNIT
|
Every model railway has points. I don't consider a layout to be complete
without at least one. Without them, the layout is a train set!
Many of these points are switched remotely due to their distance from the
operator or inaccessibility in tunnels etc.
Their method of control is usually electrical and up to now a number of problems
have been associated with these circuits. They had the tendency to overheat
the solenoids and even burn them out. If this happened, the points, and even
the track, could be damaged.
The electrical control of a set of points is simple. Electrical energy is
converted to mechanical movernent via a solenoid actuator. This device is
called a 'POINT MOTOR'. They are mounted under or near the point in such
a way that the movement sets the blades of the points for one direction or
the other.
This involves a linear movement of about 5mm. To create this movement. the
simplest device is the solenoid. It is simply a coil of wire wound on a former.
Inside the former is an iron actuator or slug which can be pulled into the
coil when the power is applied. By placing two of these coils end-to-end,
a forward and reverse motion can be created. These arrangements are called
'Switch Machines' or 'Point Motors'.
These two-solenoid point-motors are usually switched by short pulses of
electricity. The pulse length is often determined by the operator or by a
simple spring-loaded switch.
But there are several problems with this arrangement. Point motors require
a considerable amount of current for their operation. This means the full
capacity of the transformer will be needed. Any other items using the same
supply will suffer.
There are other problems too. The high currents will play havoc with switches.
The back emf (reverse voltage) generated by the solenoid is sometimes sufficient
to weld the switch closed. This will keep the current flowing through the
solenoid and it will over-heat very quickly.
|
Our CAPACITOR DISCHARGE UNIT overcomes all these problems. Capacitor Discharge
Units (CDU) supply a high current 'burst' to the solenoid. This current burst
is over by the time the switch contacts open. thus eliminating back emf across
the switch contacts. Should a solenoid be left in circuit, the current flowing
through it (after the initial surge) will be less than 50mA. This won't even
be enough to warm the coil!
|
Very few components are needed to make this unit. as can be seen from the
simplicity of the circuit diagram. R1 can be a 47OR 1 watt resistor or four
2K2 1/4 watt resistors in parallel.
HOW DOES IT WORK?
The AC voltage (16v) at the input of the CDU is rectified by D1. This diode
passes every positive half-cycle of the AC and blocks the negative half-cycle.
Assuming no solenoid is connected to the CDU, R1 pulls the base of 01 high,
switching ON the transistor and allowing current to flow through it (from
C to E), to charge the capacitors Cl and C2.
These are the reservoir capacitors that will supply the surge of current
to the solenoid.
D2 and D3 are protection diodes which prevent any back emf from damaging
the transistor or capacitors.
This is what happens when a solenoid is connected across the output of the
CDU:
The reservoir capacitors will discharge through 03 into the solenoid. The
low impedance of the solenoid (typically 3 ohms) is now holding the base
of the transistor LOW, switching it OFF. The only current now flowing is
going through R1 and the solenoid.
|
|
This current is less than 50mA. The transistor remains OFF preventing the
charge-current reaching the solenoid.
Removing the solenoid from the output of the CDU will allow the base of the
transistor to be pulled HIG H by R1. The transistor will turn on and charge
the reservoir capacitors again, ready for the next operation. Recharge time
is less than half a second.
CONSTRUCTION
Assembly of the PC board is straight-forward. Four 2k2 1/4watt resistors
are wired in parallel to form R1. A 470R 1 watt resistor could be used but
1/4watt resistors will look much neater. The transistor is bolted to the
PC board with its base and emitter leads soldered and trimmed. It requires
no insulation or heatsink.
The capacitors can be rated at 25v if the unit is to be operated on 15 -16v
AC. If connected to 18 -20v, the capacitors must be rated at 35vw.
NOTE: Train transformers often have an output of 15 to 16v when Labelled
12v, so this must be taken into account. (They drop to 12v on full load).
A single 2200mfd capacitor can be substituted for the two 1000 mfd capacitors,
If a more powerful unit is required, an extra 2200mfd capacitor can be added.
Care must be taken with orientation of all components other than the resistors.
Any error will result in damage to some or all the components.
How to wire the capacitor discharge unit into your point switching system.
Capacitor Discharge Unit Parts List
-
1-1K
-
4 - 2K2
-
2 - 1000 mfd 25v-35v. See text.
-
3 - 1N4002 diodes
-
1 - 3mm red LED
-
1 - 2N3055
-
2 - Nuts & bolts
-
1 - Capacitor Discharge Unit PCB
-
Artwork (Gif
300dpi)
'Shift + Click to save'
|
A commercial unit and a home made point
motor alongside an N guage point
|
CONNECTING THE UNIT
Disconnect the wires of your existing system from the transformer and connect
them to the output of the CDU. Connect the input of the CDU to the transformer.
The system is now ready for operation. See the completed wiring diagram for
the connections to the capacitor discharge unit.
The LED can be placed on the main control panel of the layout to indicate
the condition of the unit. The LED will light to indicate when the unit is
ready. When a point is operated, the LED wilt extinguish, then come back
on as the capacitor charges. If it remains extinguished, it indicates a fault
is present and the solenoid may still be in circuit. No other points can
be operated until this is fixed, but at least the solenoids will not be damaged!
Main Index
KIts And Projects
Basic Theory
Return to the top
This article was taken from
Talking Electronics